Novec 1230 system design pdf

Design and installation of an engineered kidde ecs systems, clean. The novec 1230 system uses a fluid fluoroketone to extinguish a fire. Sinorix 1230 clean agent extinguishing systems siemens. Novec 1230 fluid has the highest margin of safety for human occupancy among clean agents, including inert gas. Identification product name 3m novec 1230 fire extinguishing agent, pressurized and nonpressurized recommended use of the chemical and restrictions on use fire extinguishing agentidentified uses. Safety data sheet 3m novec 1230 fire extinguishing agent. Novec 1230 fluid has a zero ozone depletion potential, a. Lethal at design concentration 1 2008 nfpa 2001 and nfpa 12. The cost effective and sustainable alternative to halon. The sevo 1230 force500 clean agent fire suppression system is a revolutionary new technology for clean agent systems that utilizes 3m novec 1230 fire protection fluid and its unique ability to be pressurized to 500 psi 34. It also has a higher safety margin than other clean. System depictions, calculations, graphs or reports pro vided by the manufacturer or private labeler of the prod ucts, described in this manual, are for illustrative pur poses only, and are not warranted to be representative or descriptive of any specific system, installation or design, or of the performance of or results attainable through same. With 50 years of experience, gielle is the specialist in fire safety. The clear, colorless agent has zero ozone depletion potential, an atmospheric lifetime of just five days, and a global warming potential of 1.

It is an excellent solution for the protection of highvalue assets, business processes and people. For the direct novec 1230 systems, the firetrace tubing performs three functions. A novec 1230 fluid is designed to help protect continuity of operations because, unlike water, it does not damage. Typical fire suppression design concentrations for most. A growing minority of firms have hired fpes, sprinkler design technicians, and many have utilized the interest of existing employees in crosstraining into fire protection as their goto people in the development of sprinkler specifications and establishing basic design criteriabasic design. The clear, colorless agent has zero ozone depletion potential, an. We offer full technical design on novec 1230 systems and we can provide a quotation within 4 hours from your enquiry. System design the kidde engineered fire suppression system comprises novec 1230 fluid stored in cylinders connected to distribution pipework and specially designed discharge nozzles. Novec 1230 novec 1230 is a registered trade mark of the 3m. Sapphire suppression systems, also known as novec1230.

Fire suppression limited offer both preengineered novec 1230 fire suppression systems which require little or no distribution pipe, and engineered novec 1230 fire protection systems tailored madedesigned for its application. Design, supply and install a complete clean agent total flooding fire suppression system using novec 1230 fire protection fluid hereafter referred to as system. It shall not be used as a substitute in determining material and quantity requirements as defined in kidde fire systems design manuals and applicable nfpa standards. Novec 1230 systems are not suitable for the ships cargo holds. When designing a new system, its important that you specify an agent thats. We have our own fm200 filling plant based in our head offices in bristol. Feb 16, 2016 the janus fire systems sv 500 series clean agent fire suppression system utilizes 3m novec 1230 fire protection fluid as the extinguishing medium. Can i purchase a novec 1230 fluid fire suppression system from 3m.

Clean agent suppression systems using novec 1230 fluid. Novec 1230 fluid is available in two sizes of containers. The volume of the building in cube metres, choose the coefficient for fire protection in the building. Firetrace direct novec 1230 automatic suppression systems. Kiddefenwal assumes no responsibility for the application of any systems. Upon discharge of the preengineered novec tm 1230 fire suppression system, the extinguishing agent floods the compartment with an electrically nonconductive, noncorrosive vapor that stops the combustion process by physical means. The term novec 1230 employed throughout this manual refers to the extinguishing agent dodecafluoro. Engineered hydraulic flow program used to predict the two phase flow of novec 1230 through a pipe network. Vsh1230 clean agent fire suppression system novec 1230 extinguishing agent. Identification product name 3m novec 1230 fire extinguishing agent. It distrib utes uniformly throughout the hazard zone, and. Novec 1230 fluid is low in toxicity and environment impact.

Owners operation and maintenance manual control fire systems. Global distribution supported by experienced fire extinguishing specialists. In addition to its favorable safety and environmental profiles, novec 1230. Drafting and estimation 3m novec 1230 fire protection fluid. Fill manual for 3m novec 1230 fire protection fluid.

Novec 1230 fluid even offers the lowest extinguishing concentration of all currently authorized extinguishing agents. Jan 11, 2019 the novec 1230 fire suppression system developed by 3m is a clean agent system. Seafire novec tm 1230 fire suppression systems are designed to induce a minimum atmospheric concentration of 5. Design, installation and maintenance manual fire protection systems.

However, there are many types of fire suppression systems to choose from so it can be difficult to decide which is right for you. We offer drafting and evaluation calculations of the required amount of 3m novec 1230 fire protection fluid within the given parameters. It also offers a safety margin of up to 100% thats higher than any other type of clean. This agentair mixture has a heat capacity much larger than that of air alone. In addition to its favorable safety and environmental profiles, novec 1230 fluid is a highlyeffective fire extinguishant, designed to suppress fires quickly without powering down and. Contact carl busian at 18009191288 ex 201 to discuss your novec fire suppression system needs. Upon discharge, novec 1230 fluid creates a gaseous mixture with air. Novec 1230 fluid fk5112 is a fluorinated ketone that is stored as a liquid and discharged as a gas. Sapphire fire suppression systems sapphire cleanagent. Safety data sheet 3m novec 1230 fire extinguishing. Download the 3m novec 1230 fire protection fluid brochure pdf, 1. When the detectiondischarge tubing is installed within the limitations stated in the manual, no hydraulic calculations are required to determine pressure drop, agent flow, or discharge time.

Ecsfire suppression system with novec1230 fire protection fluid august 2014 page 1 of 7 part 1 general 1. Two of the most common fire suppression systems are the novec 1230 and fm200 systems. This manual is intended to clearly and accurately reflect the kidde engineered fire suppression system designed for use with 3m novec 1230 fire protection fluid. Engineered fire extinguishing systems utilizing 3m novec 1230 fire protection fluid. It shall not be used as a substitute in determining material and quantity requirements as defined in kidde fire systems design. The clear, colorless agent has zero ozone depletion potential, an atmospheric lifetime of just five days, and a.

If novec 1230 systems are installed inside cargo pump rooms, all components shall be certified for use in hazardous areas, the design gas concentration shall be increased and the system. The novec 1230 extinguishant is then deployed via this diffuser directly into the heart of the fire. Vsh1230 clean agent fire suppression system novec 1230. Kidde marine novec 1230 engineered fire suppression system.

Our mx 1230 fire extinguishing system uses 3m novec 1230 fire protection fluid, which will not damage electronics and leaves no residue behind. Ecsfire suppression system with novec 1230 fire protection fluid august 2014 page 2 of 7 a. Pdf, 510 kb, or visit the fire suppression novec 1230 webpage to learn more. Novec 1230 systems extinguishing agent 3m novec 1230 fire protection fluid novec 1230 is a fluorinated ketone fk5112 dodecafluoro2meth.

In janus fire systems clean agent fire extinguishing systems, the novec 1230 fluid is stored as a liquid in specially designed steel cylinder assemblies fitted with forged brass, differential pressure. Novec 1230 fluid design concentrations continued fuel design. Safety data sheet file no incoming sds novec 1230 00 sds. Novec tm 1230 removes heat energy from the fire to the extent that the combustion reaction cannot sustain itself. Proprietary janus design suite flow calculation software. Featuring an excellent safety profile with a 20year environmental warranty, novec 1230. The novec 1230 fire suppression system developed by 3m is a clean agent system. Protect valuable equipment, people and assets with a clean agent fire suppression system using 3m novec 1230 fire protection fluid. Those responsible for the agent fill or agent refill of these systems should read this entire manual. The novec 1230 extinguishing concentration for normal heptanes cup burner method is approximately 4. Although novec 1230 fluid has negligible toxicity in concentrations needed to suppress most fires, certain safety considerations must be observed when applying and handling the agent.

The sevo 1230 force500 clean agent fire suppression system is a revolutionary new technology for clean agent systems that utilizes 3m novec 1230 fire protection fluid and its unique ability to. Fire protection concentration of 3m novec 1230 3m novec. Its 500 psi operating pressure provides ultimate design flexibility and ensures that the necessary amount of agent. This publication describes the operation, installation and maintenance of the system. The sevo 1230 force500 clean agent fire suppression system is a revolutionary new technology for clean agent systems that utilises 3m novec 1230 fire protection. None generally required for adequately ventilated work situations. It also has a higher safety margin than other clean agents, making it extremely. Contact an aft specialist for help with novec 1230, including the associated detection and control equipment. System in this manual system refers to the extinguishing equipment and does not include any detection system which may initiate an agent release. In conclusion novec 1230 prior to 1st january 2018 was the most expensive of the agents we use for fire suppression system, but with the massive increase in price of fm200 due to an eu reduction of 36% has meant novec 1230 is now the only real alternative to inert gas.

Automated extinguishing system based on clean agent novec 1230 fluid sinorix 1230 is the latest generation of our chemical extinguishing systems, offering a range of unique features and benefits. Q what operations and valued assets is novec 1230 fluid used to protect. Novec 1230 fire suppression systems american fire technologies. The firetrace system requires no external power source or separate detectors and owing to its simple design. The atmospheric lifetime of novec 1230 fluid is estimated to be in the range of 35 days and with a global warming potential of 1, it is considered that the novec 1230 fluid has no measurable impact on climate change. Novec 1230 clean agent fire suppression system is used extinguished any fire hazard. Novec is calculated to discharge within 10 seconds, and is normally calculated at a 4. Designed for use with 3m novec 1230 fire protection fluid.

This calculation tool is intended for use in developing approximate estimates of the material and equipment budgeting purposes. Novec 1230 is not a direct replacement for existing halon 1 installations due to the difference in agent quantity and discharge characteristics the minimum novec 1230 design concentration for class a hazards is 4 2% for ul listed systems. The federal state of the government department of allrussian research institute for fire protection fgu vniipo of emercom of russia held tests to produce measurements of the minimal fire protection. Copy and paste the following text into your specification or download the full specification example summary of work a. Using the form for calculation of the flow rate of the fire protection agent 3m novec 1230, please enter. For example, novec 1230 fluid is a liquid at room temperature and has been super pressurized with dry nitrogen.

Due to the dramatically lower gwp, greenhouse gas emissions from discharge of novec 1230. The federal state of the government department of allrussian research institute for fire protection fgu vniipo of emercom of russia held tests to. Ecs fire suppression system with novec part 1 general. Novec 1230 fluid has a global warming potential gwp of less than one while hfcs typically have a gwp of more than 3000. Things to consider when specifying clean agent systems. Generally, a system using novec 1230 fluid will extinguish a fire even before it reaches the flame stage. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems. Novec 1230 fluid is a clear, colorless and low odor liquid perfectly suited to protect high value assets in areas that may be normally. A growing minority of firms have hired fpes, sprinkler design technicians, and many have utilized the interest of existing employees in crosstraining into fire protection as their goto people in the development of sprinkler specifications and establishing basic design criteriabasic design criteria. The firetrace system requires no external power source or separate detectors and owing to its simple design ensures that all of the extinguishant is always deployed in the fire area. Novec 1230 fluid contains neither bromine nor chlorine and has zero 0zone depleting potential.

Novec 1230 is not a direct replacement for existing halon 1 installations due to the difference in agent quantity and discharge characteristics the minimum novec 1230 design concentration for class a hazards is 4 2% for ul listed systems and for fm approved. Certified manufacturer of fire suppression system using novec 1230. Although the design of a new novec 1230 system will be similar to a fm200 system. It is a liquid at room temperature, with a low vapor pressure, which allows for ease in handling, storage, and shipping. Design, supply and install a complete clean agent total flooding fire suppression system using novec 1230 fire protection fluid hereafter referred to as system which meets all the performance criteria described herein. The sapphire system uses 3m novec 1230 fire protection fluid for total flooding applications. This system reacts quickly to a fire, leaves behind no residue, and is electrically nonconductive. Novec 1230 fluid is a fluoroketone, while chemical clean agents like fm200 are hfcs hfc227ea. The sapphire clean agent system quickly suppresses fires and protects. Whether you need portable fire equipment, service and maintenance, or largescale fire suppression systems for mining, marine, industrial, commercial and retail use. The ansul sapphire system uses 3m novec 1230 fire protection fluid for total flooding applications. Discharge of a fire protection system using novec 1230 fluid in place of an hfc extinguishing agent results in significantly reduced greenhouse gas emissions. The manufacturersupplier of the system hardware and components shall have a minimum of fifteen 15 years experience in the design and manufacture of systems.